Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 160
Filtrar
1.
Trials ; 25(1): 267, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627819

RESUMEN

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Humanos , Anciano , Persona de Mediana Edad , Prótesis de Recubrimiento , Flujo de Trabajo , Mandíbula/cirugía , Satisfacción del Paciente , Impresión Tridimensional , Prótesis Dental de Soporte Implantado , Ensayos Clínicos Controlados Aleatorios como Asunto
2.
Artículo en Inglés | MEDLINE | ID: mdl-38498786

RESUMEN

Single implants are a predictable treatment, and immediate loading can be an option with acceptable survival rates. Clinical and patient-centered outcomes comparing immediate and delayed protocol of single implants are unclear. The purpose of this study was to assess complications, satisfaction, and quality of life of patients rehabilitated with delayed and immediate loading single crowns. An electronic search was conducted in PubMed/MEDLINE, Scopus, Web of Science, Cochrane Library, and Embase databases up to February 2023. Only prospective studies, randomized and non-randomized clinical trials comparing immediate and delayed loading were included. For the quantitative analysis, dichotomous and continuous variables were evaluated with a 95% confidence interval. A total of 20 studies were evaluated. No statistically significant difference between protocols was observed: satisfaction (I2: 0%; P = 0.42), quality of life (I2: 0 %; P = 0.05), biological complications (I2: 9%; P = 0.17) mechanical complications (I2: 58%; P = 0.84), and survival rate (I2: 0%; P = 0.38). Subgroup analysis showed significant differences only for marginal bone loss when immediate implants were placed in the mandible (IÇ: 15%; P = 0.01) and posterior zone (I2: 0%; P = 0.001). Complications and patient-centered outcomes for immediate single-implant crowns were comparable to delayed loading. Scientific evidence showed no significant difference between loading protocols for survival rates. Although several factors could interfere with the complication events, implant failures, and marginal bone loss, the subgroup analysis evidenced that only immediate implants placed in the posterior mandible zone had higher statistically significant mean marginal bone loss.

3.
J Prosthodont ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38487989

RESUMEN

PURPOSE: The objective of this retrospective study was to evaluate the effect of the interproximal contour of single external hexagon implant restorations on the prevalence of peri-implantitis. MATERIAL AND METHODS: Records of 96 patients and 148 external hexagon (EH) implants with time in function ranging from 1 to 17 years were included in the study. The most recent clinical and radiographic data were collected from records and the prevalence of peri-implantitis was defined according to the 2017 World Workshop on the Classification of Periodontal and Peri-implant Diseases and Conditions. Marginal bone level (MBL), emergence angle (EA), emergence profile (EP), and crown/implant platform horizontal ratio (CIHR) were obtained from periapical radiographs. Dichotomous variables at the patient- and implant level were compared with association tests. Mann-Whitney U-Test was performed to compare continuous quantitative values between the studied groups. Binomial logistic regression was conducted to identify risk indicators associated with the peri-implantitis event at the patient- and implant level, with the significance level set at 5% for all tests. RESULTS: Nineteen patients (19.2%) and 24 implants (16.2%) with a mean time in function of 5.0 ± 4.7 years were classified as having peri-implantitis. No statistically significant differences concerning gender, mean age, implant location in the jaw, or time in function were observed between patients with or without peri-implantitis (p > 0.05). Of 24 implants with peri-implantitis 10 (41.7%) displayed EA ≤ 30° (16.4%) while 14 (58.3%) presented EA > 30° with no statistical difference between the groups (p > 0.05). No statistically significant associations were identified between EA, EP, or CIHR and the prevalence of peri-implantitis. CONCLUSION: The findings seem to indicate that the EA, EP, and CIHR of single restorations over external hexagon implants are not associated with the presence of peri-implantitis. However, prospective studies with larger samples are required to better ascertain such an association in the long term.

4.
J Prosthodont ; 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38305664

RESUMEN

PURPOSE: This study aimed to develop and evaluate a simple, non-destructive method for assessing the misfit and passivity of implant-retained prostheses frameworks. MATERIALS AND METHODS: To simulate the rehabilitation of a mandible posterior partially edentulous area using 3-unit screw-retained frameworks supported by two implants were fabricated and divided into the following five groups (n = 10 in each group): OP = one-piece framework cast in Co-Cr with the conventional method (control-group); Co-Cr frameworks sectioned and welded by laser (=LAS) or tungsten inert gas (=TIG); Co-Cr CAD-CAM = milled Co-Cr framework; Zir CAD-CAM = milled zirconia framework. The horizontal |X| and vertical |Y| misfits were measured using confocal laser scanning microscopy with one or both screws tightened. Data were analyzed by a two-way ANOVA with repeated measures and Bonferroni correction (α = 0.05). RESULTS: The greatest |X| misfit was observed in the OP group with both screws tightened (290 µm) and one screw tightened (388 and 340 µm). The conventional casting groups sectioned and welded by laser or TIG had lower mean values (235.35 µm, both screws tightened; and 275 µm, one screw tightened) than the OP framework. However, these values still exceeded those of the milled Co-Cr and zirconia frameworks (190 and 216 µm with both screws tightened). Across all reading conditions, every framework subjected to testing consistently maintained vertical |Y| misfit levels below the threshold of 53 µm; however, the milled frameworks exhibited higher vertical misfits than the frameworks obtained by the conventional cast method. CONCLUSIONS: The frameworks, whether cast and sectioned with laser welding or milled from Co-Cr, exhibit improved marginal misfit and enhanced passive fit when compared to other fabrication methods. Additionally, the use of confocal laser scanning microscopy is highly effective for passivity and misfit analysis.

5.
J Mech Behav Biomed Mater ; 151: 106395, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38244420

RESUMEN

OBJECTIVES: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS: The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).


Asunto(s)
Implantes Dentales , Prótesis Dental , Circonio , Soporte de Peso , Tornillos Óseos , Análisis de Varianza , Titanio , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Coronas
6.
Proc Inst Mech Eng H ; 238(2): 250-256, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38189276

RESUMEN

Resin coating in implants rehabilitation cannot always be aesthetic, durable and comfortable for the patient mainly due to the limited dimensions of the final structure. Intraoral welding technique and computer-aided designed prosthetic shells may be a solution. This in vitro study evaluates the capacity of load and the weakest point of implant-supported provisional prosthesis using welded titanium framework. Twelve samples were produced to simulate an implant supported fixed prosthetic bridge. Two implants (Ankylos; Dentsply Sirona Implants; Germany) were inserted inside blocks of nanoceramic material produced with a stereolithographic 3D printer. A polymethylmethacrylate (PMMA) resin shell was performed with CAD/CAM and relined on welded framework. Six samples were produced with the same procedure reducing resin thickness. The samples were subjected to fatigue test (6,500,000 cycles) using ElectroForce 3310 fatigue machine (t1); subsequently a mechanical compression test using a universal Shimadzu AGS-X 10 machine (t2). The samples were analyzed with a photographic and radiographic documentation at t0, t1 and t2. The samples survived mechanical fatigue test without evidence of failure. The radiographic and photographic evaluation revealed the fracture of resin coating after the mechanical compression test. The samples with minimal resin thickness fractured first. Adequate assessment of the resin thickness is mandatory to improve the longevity of these rehabilitations. CAD-CAM digital prosthetic design allows us to optimize the thicknesses and the prosthetic shapes, allowing us to obtain good degrees of resistance even in the presence of reduced prosthetic spaces.


Asunto(s)
Soldadura , Humanos , Proyectos Piloto , Ensayo de Materiales , Diseño Asistido por Computadora , Computadores
7.
Clin Oral Implants Res ; 35(2): 201-219, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38050349

RESUMEN

OBJECTIVE: Evaluate the long-term outcomes of full-arch rehabilitation using immediate dental implant placement and continuous functional loading with full-fixed dental prostheses (FFDPs). MATERIALS AND METHODS: Fifty-six patients received temporary implants (n = 327) at maxillary augmentation with calvarial bone. A provisional acrylic FFDP was immediately loaded onto these implants. After 6 months, the temporary implants were replaced with definitive implants (n = 326) and immediately loaded with a second provisional FFDP (N = 55). Subsequently, a baseline radiograph was taken following a 6-month healing period. The second bridge was then substituted with a definitive FFDP. Primary outcomes included peri-implant marginal bone level (MBL) and definitive implant survival. Secondary outcomes evaluated provisional implant and prostheses survival, complications, and patient satisfaction. RESULTS: The provisional implants had a survival rate of 97.9%. One patient was excluded from further analysis due to loss of temporary implants and first FFDP. The definitive implant survival rate after 10 years was 92.2%, with a moderate but significant decrease in MBL between baseline radiography and 10 years later (-0.08 ± 0.18 vs. -0.24 ± 0.44). However, large individual variations were observed, with 65.8% of implants showing no bone loss and 9.2% showing loss ≥0.5 mm. Sinusitis was experienced by 14.3% of patients upon surgery. Patient satisfaction was high or reported no issues after protocol completion (80%). One patient lost all six definitive implants and definitive FFDP 8.2 years after implant placement. CONCLUSIONS: The described protocol can be regarded as a long-term, highly successful method for full-arch rehabilitation of atrophied maxillae while enabling continuous masticatory and speaking functionality.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Implantación Dental Endoósea/métodos , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Estudios Retrospectivos , Prótesis Dental de Soporte Implantado , Resultado del Tratamiento , Fracaso de la Restauración Dental , Estudios de Seguimiento
8.
BMC Oral Health ; 23(1): 983, 2023 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-38066579

RESUMEN

BACKGROUND: Currently, oblique placement of long implants or the use of short implants to circumvent the maxillary sinus area and provide support for fixed prostheses are viable alternatives. The purpose of this study was to compare these two treatment concepts and ascertain which one exhibits superior biomechanical characteristics. METHODS: Two different treatment concept models were constructed. The first one, LT4I, consisting of two mesial vertical implants positioned in lateral incisor regions and two distal tilted implants (45°) situated in second premolar regions of the maxilla. The second model, VS4I, includes two mesial vertical implants in lateral incisor regions and two vertically positioned short implants in second premolar regions. Numerical simulations were conducted under three loading types: firstly, oblique forces upon the molars; secondly, vertical forces upon the molars; thirdly, oblique forces upon the incisors. The maximum principal stress (σmax) and minimum principal stress (σmin) of the bone, as well as von Mises stress of the implants, were calcuated. RESULTS: Under oblique loading on the molar, higher stress values in the bone were observed in LT4I group. Under vertical loading on molar, higher stress values in the bone were also observed in LT4I group. Furthermore, little difference was found between the two groups under oblique loading on the incisor. CONCLUSION: Both treatment concepts can be applicable for edentulous individuals with moderate atrophic maxilla. Compared to tilted implants, short implants can transmit less occlusal force to the supporting tissues.


Asunto(s)
Implantes Dentales , Humanos , Prótesis Dental de Soporte Implantado , Análisis de Elementos Finitos , Maxilar/cirugía , Modelos Teóricos , Estrés Mecánico , Análisis del Estrés Dental , Diseño de Prótesis Dental
9.
Int J Oral Implantol (Berl) ; 16(4): 339-348, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37994821

RESUMEN

Incomplete orthodontic therapy can lead to severe root resorption, resulting in mobile and non-restorable teeth. This clinical report presents the diagnosis, treatment planning and oral rehabilitation of a young woman with failing dentition in the anterior maxilla due to orthodontically induced root resorption. The patient's chief complaint was mobile maxillary anterior teeth 2 years after discontinuing orthodontic treatment. Radiographic and clinical evaluations revealed a missing right first premolar and left premolars and grade III mobility from the right canine to the left lateral incisor. Due to a hopeless prognosis, extraction of the maxillary anterior teeth was planned, followed by grafting procedures. Four implants were immediately placed in the fresh sockets of the canine and central sites, and a removable provisional appliance was delivered to contour the soft tissues involved. The final restorations consisted of two three-unit layered zirconia implant-supported fixed dental prostheses. Well-planned immediate implant therapy and zirconia restorations can successfully replace mobile teeth with severe root resorption caused by external surface resorption from incomplete orthodontic treatment. Combining grafting procedures during implant placement can replace hard tissue lost due to extractions, whereas provisional restorations can re-establish optimal tissue architecture in the aesthetic zone. The present case offers insight into effective strategies for treating non-compliant or uncooperative patients with failing dentition due to orthodontically induced root resorption.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Resorción Radicular , Femenino , Humanos , Implantes Dentales/efectos adversos , Resorción Radicular/diagnóstico por imagen , Resorción Radicular/etiología , Resorción Radicular/cirugía , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Dentición , Estética Dental
10.
J Korean Assoc Oral Maxillofac Surg ; 49(5): 278-286, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37907343

RESUMEN

Objectives: This review assessed the performance of implant-supported fixed hybrid prostheses in 21 patients who received a total of 137 implants between 2003 and 2010. The implants were evaluated for marginal bone resorption, complications, success rate, and survival rate based on their vertical angularity, type of bone graft, and measured implant stability. Materials and Methods: One-way ANOVA and chi-square tests were used to analyze the relationships among long-term evaluation factors and these variables. The mean initial bone resorption in the implant group with a vertical angle of more than 20° was 0.33 mm and mean final bone resorption was 0.76 mm. In contrast, the mean initial bone resorption in the implant group with a vertical angle of less than 10° was 1.19 mm and mean final bone resorption was 2.17 mm. Results: The results showed that mean bone resorption decreased with an increase in the vertical placement angle of the implants used in fixed hybrid prostheses, as well as in the group without additional bone grafts and those with high implant stability. The success rate of implants placed after bone grafting was found to be higher than those placed simultaneously. Conclusion: These results suggest that implant-supported fixed hybrid prostheses may be an effective treatment option for edentulous patients, and intentionally placing implants with high angularity may improve outcomes.

11.
J Prosthodont ; 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37675589

RESUMEN

PURPOSE: The purpose of this in vitro investigation was to assess how implant depth could affect the three-dimensional positional accuracy of digital impressions made from angulated implants. MATERIALS AND METHODS: Four modified maxillary models were printed and divided into four study groups. In each model, two angulated implant analogs were placed at the sites of the first premolar and first molar at four different depths of 1 (G1), 2 (G2), 3 (G3), and 4 (G4) mm from the models' edentate area. Scan bodies were connected to the analogs, and one operator made 10 full-arch scans for each master model using an intraoral scanner. Afterward, the marginal gingival part of all models was removed, and digital scans were performed for each model using a laboratory scanner to achieve a reference STL file as the control group. One-way ANOVA and Leven's tests were used to measure and compare the 3D distance deviations across research groups after the superimposing test and control scans. RESULTS: A significant difference between research groups was revealed by trueness and precision analysis (p < 0.001). The trueness and precision results obtained for G1 and G4 were significantly better than those for G2 and G3 (p < 0.05). CONCLUSION: This study demonstrated that implant depth could affect the digital implant impressions' 3D positional accuracy.

12.
Clin Oral Implants Res ; 34 Suppl 26: 86-103, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37750526

RESUMEN

OBJECTIVE: The objectives of the study were to assess the survival, failure, and technical complication rates of implant-supported fixed dental prosthesis (iFDPs) with pontic or splinted crown (iSp C) designs in the posterior area and compare the influence of prosthetic materials and prosthetic design on the outcomes. METHODS: Electronic and manual searches were performed to identify randomized-, prospective-, and retrospective clinical trials with follow-up time of ≥12 months, evaluating the clinical outcomes of posterior iFDPs with pontic or iSp Cs. Survival and complication rates were analyzed using robust Poisson's regression models. RESULTS: Thirty-two studies reporting on 42 study arms were included in the present systematic review. The meta-analysis of the included studies indicated estimated 3-year survival rates of 98.3% (95%CI: 95.6-99.3%) for porcelain-fused-to-metal (PFM) iFDPs, 97.5% (95%CI: 95.5-98.7%) for veneered zirconia (Zr) iFDPs with pontic, 98.9% (95%CI: 96.8-99.6%) for monolithic or micro-veneered zirconia iFDPs with pontic, and 97.0% (95%CI: 84.8-99.9%) for lithium disilicate iFDPs with pontics. The survival rates for different material combination showed no statistically significant differences. Veneered restorations, overall, showed significantly (p < .01) higher ceramic fracture and chipping rates compared with monolithic restorations. Furthermore, there was no significant difference in survival rates (98.3% [95%CI: 95.6-99.3%] vs. 99.1% [95%CI: 97.6-99.7%]) and overall complication rates between PFM iFDPs with pontic and PFM iSp Cs. CONCLUSIONS: Based on the data identified by this systematic review, PFM, veneered Zr, and monolithic Zr iFDPs with pontic and iSp Cs showed similarly high short-term survival rates in the posterior area. Veneered restorations exhibit ceramic chipping more often than monolithic restorations, with the highest fracture rate reported for veneered Zr iFDPs.


Asunto(s)
Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Estudios Prospectivos , Estudios Retrospectivos , Porcelana Dental , Cerámica , Circonio , Coronas , Prótesis Dental de Soporte Implantado
13.
Heliyon ; 9(7): e17956, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37483728

RESUMEN

The aim of this study was to define the relation between load distribution and the number of implants supporting mandibular implant-supported screw-retained complete prostheses (ISCP). It is a three-dimensional (3-D) finite element study. Three models were simulated. The first one represents a 4-implant supported prosthesis (4ISP), the second one is a 3-implant supported prosthesis (3ISP) and the third one is a 6-implant supported prosthesis (6ISP). The 6ISP model showed the best bone stress distribution among all models. Its maximum stress value was 63.3 MPa. The 4ISP (98.9 MPa) showed a better bone stress distribution than the 3ISP (122.9 MPa). A flexion of the prosthesis was more important for the 4ISP than 3ISP and then 6ISP model at 10 MPa. In the 4 ISP and the 3ISP models, the anterior implants were more solicited. However, the stress was evenly distributed on the 6 implants, in the 6ISP model. Concerning, the stress distribution in bone, the uppermost stress was found in the 3ISP, then the 4ISP and then the 6ISP model. The increase of implants number reduces the stress on the bone and prosthesis and implants. The use of 6 implants to support screw-retained complete prostheses showed a better biomechanical behavior.

14.
Clin Oral Implants Res ; 34(10): 1127-1140, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37523460

RESUMEN

OBJECTIVES: To determine the association between tobacco and peri-implant diseases in a sample of patients who had received implant-supported restorations in a university dental clinic. Furthermore, the study aimed to investigate patient- and implant-related variables associated with peri-implant diseases. MATERIALS AND METHODS: The present retrospective study analyzed data from 117 patients treated with implant-supported restorations from 2001 to 2013. A total of 450 implants were evaluated. Patients were selected from an electronic database, and patient- and implant-related variables were evaluated. Detailed information regarding the smoking history (i.e., smoking status, lifetime cumulative dose, duration of exposure, intensity of the habit, and smoking cessation) was recorded. The primary study outcome was peri-implant status [i.e., health (H), peri-implant mucositis (PM) and peri-implantitis (PI)]. Univariate and multinomial regression models comparing PM and PI versus peri-implant health were conducted. RESULTS: A total of 117 subjects [55 (47%) females and 62 (53%) males] with a mean age at examination of 64.2 years (SD 11.6) and rehabilitated with 450 implants were included. The average number of implants per patient was 4.6 (SD 3.3) with a mean time in function of 8.0 years (SD 1.9). Fifty-six patients (47.9%) were non-smokers, 42 (35.9%) were former-smokers, and 19 (16.2%) were current-smokers. Thirty-nine subjects (33.4%) were H, whereas 41 (35%) and 37 (31.6%) exhibited PM and PI, respectively. At implant level, the corresponding values were 142 (31.6%), 230 (51.1%) and 78 (17.3%). In the multinomial regression model, significant associations for peri-implant diseases were observed for the mean number of implants per patient (p = .016), function time (p = .048), implants placed simultaneously with guided bone regeneration (p = .016), implant surface (p = .020), keratinized mucosa at the buccal aspect (p = .032), and access to interproximal hygiene (p < .001). In addition, ever smokers >23 pack-years exhibited a significantly higher risk for peri-implantitis (p = .002). Finally, the multinomial regression analysis revealed that subjects who had stopped smoking more than 21 years before the last examination presented a significantly lower risk of peri-implant diseases than a smoking cessation of ≤21 years (p = .028). CONCLUSIONS: Smoke intensity was associated with an increased risk of the development of peri-implantitis. Moreover, the risk of peri-implant diseases might be similar in those subjects who had stopped smoking for more than 21 years with respect to never-smokers.

15.
Eur J Prosthodont Restor Dent ; 31(4): 407-415, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-37382334

RESUMEN

Quantifying in edentulous patients the facial collapse and whether complete conventional denture (CCD) and implant-supported fixed complete denture (ISFCD) can restore the facial proportions to match those of a dentate patient (CG) is relevant for clinical dentists. One hundred and four participants were enrolled and divided into edentulous (n=56) and CG (n=48). The edentulous participants were rehabilitated with CCD (n=28) or ISFCD (n=28) in both arches. Anthropometric landmarks in the face were marked and captured by stereophotogrammetry. Linear, angular, and surface measurements were analyzed and compared among groups. The statistical analysis was performed by an independent t-test, the one-way ANOVA, and Tukey's test. The significance level was set at 0.05. The facial collapse was quantified as a significant shortening of the lower third of the face affecting facial aesthetics in all parameters evaluated and the same was observed in comparison among CCD, ISFCD, and CG. The CCD presented statistical differences with the CG group in the lower third of the face and labial surface, and the ISFCD showed no statistical differences with the CG and CCD. The facial collapse in edentulous patients could be restored through oral rehabilitation with an ISFCD similar to those of dentate patients.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Boca Edéntula , Humanos , Adulto , Arcada Edéntula/rehabilitación , Dentadura Completa , Prótesis Dental de Soporte Implantado
16.
J Mech Behav Biomed Mater ; 142: 105847, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37127010

RESUMEN

PURPOSE: This study aimed to evaluate the stress distribution and microgap formation in implant assemblies with conical abutments made of different materials under an oblique load. MATERIALS AND METHODS: The mechanical behavior of an implant assembly with a titanium abutment was analyzed and compared with that of an assembly with a Y-TZP abutment using finite element analysis (FEA). A torque of 20 Ncm was first applied to the abutment screw, followed by oblique loads of 10 N-280 N applied to the prosthesis placed on the implant. The maximum stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated. RESULTS: No significant difference in stress distribution between the two cases was observed, with the stresses being mainly concentrated at the top half of the screw (the predicted maximum von Mises stress was approximately 1200 MPa at 280 N). The area in contact at the implant-to-abutment interface decreased with increasing load for both abutments, with the critical load for bridging the internal implant space being roughly 140 N. The maximum gap size being was approximately 470 µm with either abutment. CONCLUSION: There was no significant difference in the stress distribution or microgap formed between implant assemblies with titanium and Y-TZP abutments having an internal conical connection.


Asunto(s)
Implantes Dentales , Análisis de Elementos Finitos , Titanio , Torque , Análisis del Estrés Dental , Estrés Mecánico
17.
Clin Implant Dent Relat Res ; 25(5): 789-794, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37232408

RESUMEN

OBJECTIVE: The purpose of this cone beam computed tomography (CBCT) study was to determine the frequency percentage of screw-retained crown using angulated screw channel (ASC) abutment for single immediate implant placement and provisionalization (IIPP) in the esthetic zone. METHODS: The CBCT images of 200 patients without disease and without metal restorations in maxillary anterior teeth were evaluated. The mid-sagittal-sectional CBCT images of maxillary anterior teeth (#6-#11) were created in an implant planning software, screen-captured, and transferred to a presentation program. Template of tapered implants with diameter of 3.5 mm (for central and lateral incisors) and 4.3 mm (for central incisors and canines) and lengths of 13, 15, and 18 mm were applied to the sagittal images to identify the IIPP cases. To qualify for IIPP, the implant must engage >35% bone with at least 1 mm of surrounding bone and no perforations. The IIPP cases were further divided into straight screw channel (IIPPSSC) abutment or 25-degree angulated screw channel abutment (IIPPASC), based upon its restorability. The frequency percentages of possible IIPP, IIPPSSC, and IIPPASC were reported and compared among all maxillary anterior teeth. RESULTS: A total of 1200 maxillary anterior teeth sagittal images from 200 patients (88 male and 112 female) with a mean age of 51.3 years (range 20-83 years) were evaluated in this study. The overall frequency percentages of IIPP, IIPPSSC, and IIPPASC possibility were 84% (74%-92%), 14% (10%-24%), and 75% (66%-87%), respectively. CONCLUSION: Within the limitations of this CBCT study, 90% of single IIPP in the esthetic zone can be restored with screw-retained crown when utilizing ASC. In addition, the possibility of using a screw-retained restoration following IIPP increases about five times with ASC abutment compared to the SSC abutment.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estética Dental , Coronas , Tomografía Computarizada de Haz Cónico/métodos , Tornillos Óseos , Proceso Alveolar , Maxilar/diagnóstico por imagen , Maxilar/cirugía
18.
J Biomech Eng ; 145(9)2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37195691

RESUMEN

Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.


Asunto(s)
Implantes Dentales , Humanos , Estrés Mecánico , Análisis de Elementos Finitos , Mandíbula/cirugía , Análisis del Estrés Dental
19.
J. res. dent ; 11(1): 1-6, May 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513028

RESUMEN

The development of dental implants has revolutionized the rehabilitation possibilities for partially or totally edentulous patients. The long-term success of the dental implant depends on osseointegration and this is achieved by the combination of two essential stabilities: primary and secondary. Implant-supported prostheses are a great evolution for these treatments, positively interfering in the quality of life of the population, as they generate function and aesthetics for the patient. Thus, the present study aimed to radiographically evaluate complete dentures supported by an external hexagon conical implant in the anterior region of the mandible. More specifically, to evaluate the feasibility of using these implants in cortical bone of the mandible, to verify the success rate regarding the significance of peri-implant bone loss and to compare peri-implant bone loss between patients.

20.
Immun Inflamm Dis ; 11(3): e812, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36988245

RESUMEN

OBJECTIVE: To assess the influence of systemic sclerosis (SSc) on the survival rate of dental implants in SSc patients receiving implant-supported treatments. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) Statement and the Cochrane Collaboration's guiding principles were followed during the study's execution. The data from three databases, PubMed, Google Scholar, and Scopus, available until January 2023, were used to compile the material for our research. Only English-language publications were submitted for this research and evaluated based on their titles, abstracts, and full texts. For performing a quality assessment, quality scores were calculated. RESULTS: The total number of patients and implants studied were 37 and 153, respectively, all having had scleroderma. The patients' ages ranged from 28 to 77 years old, with a mean (SD) age of 58.16 (12.88). All the patients in the case reports and most in the case series study were female. The range of follow-up duration was from 1 to 10 years. In case report studies, the survival rate was 100%; in case series, it was 89.2%. CONCLUSION: The SSc status had no discernible impact on the implant survival rate. Implant-based treatments in SSc patients should not worsen the overall morbidity and should not conflict with systemic treatments. Before starting implant therapy, a thorough risk assessment is essential, though.


Asunto(s)
Implantes Dentales , Esclerodermia Sistémica , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Masculino , Bases de Datos Factuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...